Skip to content

Zoom Axis 'At Limit' Notice When No Soft Limits Are Set

CONFIRMED ALL RIGS

Summary

If the Zoom axis (or any other axis) has empty soft limit values in Axis Setup, Flair shows a "Notice — zoom [is] at limit" warning when the axis value is 0.00. This is because with no limits set, Flair treats 0 as being at the boundary. Fix: either set actual soft limits that include 0 in the valid range (e.g. min = -10, max = 10), or disable the axis with middle-click if it is not being used.


Symptoms

  • Move shows a Notice or warning related to the zoom axis being "at limit" or "on limit"
  • The zoom motor is not actually at a physical stop
  • Issue appears when zoom value is 0.00 (the default/start position)
  • There are no explicit soft limit values entered in Axis Setup for zoom

Fix

Option A — Set soft limits that include 0

  1. Open Setups → Axis Setup → Zoom
  2. Set the Min limit to a value below 0 (e.g. -10 or -0.01)
  3. Set the Max limit to the full zoom travel distance
  4. Save — the notice at 0 should disappear

Option B — Disable the axis (if zoom is not used)

  1. In the main Flair axis bar, middle-click the Zoom axis button to disable it
  2. The button turns flat/grey — axis is suppressed and no longer checked for limits

Option C — Clear the limits entirely

In some versions, deleting the limit values (leaving them completely empty) resolves the spurious notice — but this is less reliable than setting explicit values.