Measure Optical Cannot Be Zero — Must Be Film Plane to Tilt Axis Distance¶
Summary¶
In Flair camera/lens setup, the Measure Optical value (also referred to as "Optical Offset") cannot be left at 0.00. It must be set to the physical distance from the camera's film/sensor plane to the middle of the tilt axis. Setting it to zero causes incorrect kinematics — Flair cannot correctly calculate camera position for Cartesian moves or target tracking. This is a fundamental camera measurement, not an optional field.
Symptoms¶
- Camera/lens setup has Measure Optical set to 0.00
- Cartesian moves don't go where expected
- Target tracking behaves oddly — camera doesn't orbit correctly around the target
- Periprobe / probe / snorkel setups may show this as an X (Front) Nodal Offset
What Measure Optical Is¶
Measure Optical = the distance from the camera's film/sensor plane (indicated by the Φ mark on the camera body) to the centre of the tilt axis of the robot.
This is a physical measurement you take with a tape measure. It is typically 3–10 cm for most lens/camera combinations. It is never zero because the camera body and lens always place the sensor some distance in front of the tilt axis.
For a standard lens: measure from the camera body's film plane marking to the tilt axis of the robot head.
For a probe/periprobe/snorkel lens: use the X (Front) Nodal Offset field with the distance from the sensor to the front optical element of the periscope, as per the Probe/Snorkel lens setup mode.
Fix¶
- Physically measure the distance from the camera film plane (Φ mark) to the tilt axis centre
- Enter that value in Setups → Camera/Lens Setup → Measure Optical
- Values are typically in the range 3 cm – 15 cm (0.030 m – 0.150 m) — never 0
- For periprobe setups: use the lens's Tilting Lens mode; set X (Front) Nodal Offset to the distance from sensor to lens front; all other values at 0 (per Timothy Heys Cerchio's advice)
For Laowa probe setups
Timothy Heys Cerchio: "Measure from Sensor to lens front and use that value as X (Front) Nodal Offset. All other values at 0"
confidence_score: 0.90
WhatsApp Excerpts¶
[18/3/2023, 7:46:23 am] ~ Chavez.Camera: Don't forget to add measure optical offset.
[Context from March 2023 thread — approx line 15084-15090]: "Measure optical...Can't be 0" — operator reminder during Periprobe setup discussion.
Related Issues¶
- See also: Probe Camera Mount / Tube Length
- See also: Probe / Macro Setup Roundup
- See also: Probe / Macro Target Behind Nodal Point
- See also: Laowa Periprobe — Barrel Rotation Focus Conflict