XLR Trigger Box For Lights - Relay Switching, Current Limits, and DMX Alternative¶
Summary¶
The XLR Triggers Box can switch outputs from Flair, but using it to turn modern lights on/off requires care. The chat answer separated three cases: trigger a DMX cue when possible, use a properly rated relay/contactor for higher-current switching, and do not assume digital ballast/LED fixtures behave like tungsten bulbs when power is cut and restored.
Symptoms / Questions¶
- Operator wants to connect a light to the trigger box for on/off control.
- Light may be an Aputure / digital ballast / LED fixture.
- User is unsure whether to use trigger output, mains breakout, relay, or DMX.
Settings Location¶
| Task | Flair location |
|---|---|
| Program trigger output frames | Setups -> Outputs |
| Test trigger outputs | Setups -> Outputs -> Test Outputs |
| External camera trigger | Setups -> External Camera Setup |
| DMX alternative | Setups -> DMX or Setups -> External Devices -> DMX / Root DMX |
Community Solutions¶
[LIKELY] Prefer DMX For Modern Lights¶
For Aputure-style digital lights, triggering DMX is usually more appropriate than cutting mains power. Modern LED fixtures and digital ballasts may not switch predictably like tungsten lamps when their mains input is toggled.
Confidence: 0.76
[LIKELY] Use A Proper External Relay For High Current Loads¶
If the light/effect must be power-switched, use the trigger box to drive a properly rated high-current relay or contactor with a 12V or 24V DC coil, rather than asking the trigger box relay to carry a questionable load.
Confidence: 0.74
[CONFIRMED] Respect Trigger Box Current Ratings¶
The Triggers Box Mk II QSG lists relay output limits and pinouts. The chat referenced 8Amp Max; the QSG also states output constraints including 250VAC/30VDC 8A Max at the connector reference, and separate relay-output notes for voltage/current and inductive-load limits. Treat inductive loads conservatively and ask MRMC for final confirmation.
Confidence: 0.82
Evidence¶
| Timestamp | User | Evidence |
|---|---|---|
| 2026-05-19 21:14 | Julio Oliveira | Asked how to connect a light to the trigger box to get it on/off. |
| 2026-05-19 21:49 | Stafford | XLR trigger box has mains breakout cables; thought maybe 10A, needed QSG check. |
| 2026-05-19 21:55 | Timothy Heys Cerchio | Shared Triggers Box (Mk II) Quick Start Guide MRMC-1282. |
| 2026-05-19 21:56 | Timothy Heys Cerchio | Stated 8Amp Max. |
| 2026-05-19 22:05 | Timothy Heys Cerchio | Warned modern digital ballast lights like Aputures may not work well with mains power switching. |
| 2026-05-19 22:30 | Chavez.Camera | Suggested DMX is probably best. |
| 2026-05-20 04:15 | Peter Constan-Tatos | Best method is high-current relay with 12V or 24V DC coil. |
WhatsApp Excerpts¶
- 2026-05-19 21:14 - ~ Julio Oliveira: Hey, guys. How do i conect a light to the trigger box to get it on/off?
- 2026-05-19 21:49 - ~ Stafford: XLR trigger box has mains breakout cables for 110V I'd need to check the QSG but i think 10A
- 2026-05-19 21:55 - Timothy Heys Cerchio: Triggers Box (Mk II) Quick Start Guide MRMC-1282-_260519_135531.pdf • 28 pages
- 2026-05-19 21:56 - Timothy Heys Cerchio: 8Amp Max
- 2026-05-19 22:05 - Timothy Heys Cerchio: Though, I fear, modern digital ballast lights like the Aputures might not actually work well with Mains Power switching ON/OFF... 😬
- 2026-05-19 22:07 - Timothy Heys Cerchio: Or, let's say, definitely not like an analogue tungsten light bulb would 😉
- 2026-05-19 22:30 - ~ Chavez.Camera: Probably best to trigger DMX
Official Documentation References¶
Triggers Box Mk II QSG - PDF p.11: using trigger outputs and relay behavior
Triggers Box Mk II QSG - PDF p.20: input/output connector reference
Triggers Box Mk II QSG - PDF p.24: XLR pinout and 250VAC/30VDC 8A max note